scxi-1314. Part Numbers:187212B-01, 777687-14 SCXI-1127. scxi-1314

 
 Part Numbers:187212B-01, 777687-14 SCXI-1127scxi-1314  I'm guessing that channel 2 of your 1314 has a 120 Ohm resistor installed, and the other channels

44DSUB to 37DSUB 1M. Find the National Instruments SCXI-1328 at our website: Click HERE. Mechanical Dimensions. National Instruments has a variety of connectivity options for SCXI, including front-end terminal blocks, rack-mount terminal blocks, and DIN-rail mountable terminal blocks. The SCXI-1520 module provides parallel measurement of up to 8-channels simultaneously, capturing and multiplexing into a single data stream to a PC acquisition card (National Instruments, M-Series PC-6221) with a maximum sampling rate of 250 kS/s. SCXI-1314. com ¥ ni. vi ‏826 KB. JPG ‏187 KB The SCXI-1520 accepts quarter-, half-, and full-bridge sensors. This document provides the steps to install and configure a typical cascaded SCXI module system. Excitation Output Channels. The "DAQmx channel property node" has an element. The SCXI platform can be used with the NI-DAQ driver for a variety of applications, including data acquisition and signal conditioning. I am using SCXI-1520 and SCXI 1314 to measure strain from 4 strain gauges. The SCXI-1314 terminal block is used with the SCXI-1520 universal strain/bridge module enabling you to conveniently connect strain gauges through screw terminals. 1 as described in the preceding text. Remove slack in the NI 9935 wiring and secure the wires or cable by threading a zip tie through the two strain relief holes on the NI 9935 opening. Real or not (we think maybe it's a sign of bad) I feel like the ADC. 16 pages. Mod5: SCXI-1520. Once I right clicked SCXI 1001 under device and Interfaces in MAX>> test>>I found a pop up window as “Verify SCXI chassis: Configuration specifies a SCXI -1600 module but nothing was detected”. Run the signal wires through the strain-relief opening. Ensure the modules are setup properly in the Modules tab to match the physical configuration of the chassis. By choosing this system over using benchtop instruments, United Technologies Research Center saved. SCXI-1305. To install and use your SCXI-1314 terminal block, you need the following items: SCXI-1314 terminal block SCXI-1314 Universal Strain Terminal Block Installation Guide Eight precision 120 Ω resistors for use in quarter-bridge completion circuits (if using 120 Ω strain gauges) SCXI chassis SCXI-1520 module SCXI-1520 User Manual Re: SCXI-1314T. SCXI-1520 (Load cells) 2 SCXI-1314 (Load cells) 2 SCXI-1122(RTDs) 2 SCXI-1322 (RTDs) 2 SCXI-1161 (Relays) NI 6713 CWaveform generator)Rate the SCXI-1314. 7 stars - 1895 reviewsNational Instruments SCXI-1314: 1: Data acquisition controller Computer software: National Instruments SCXI-1600 PC with LabView: 1 1: Table 2 lists the technical information of the strain gauges used. Win7 Enterprise. com. Mod4: SCXI-1520 w/ SCXI-1314. com Do not loosen or re-orient the safety-ground lug hardware when connecting the safety-ground wire; to do so reduces the safety isolation between the high voltage and safety ground. an SCXI-1314 terminal block, connect the DMM to the P0+ and P0– output terminals of the SCXI-1314. The mobile DAQ system achieves seamless integration among signal conditioning, data acquisition, and synchronization that benchtop instruments would not have achieved. Then, follow the steps below: 1. scxi-1314の端子台とscxi-1520モジュールを使用して、120Ωひずみゲージから信号を取りたいと考えています。daqmxを使用し、maxでグローバルチャンネルの設定を行いたいのですが、キャリブレーションを行うとエラーが出てしまいます。何の設定がおかしいのでしょうか。Summary of Contents for National Instruments SCXI-1000. Connections, including power signals to ground and vice versa, that exceed any of the maximum signal ratings on the SCXI device can create a shock or fire hazard or can damage any or all devices conn ected to the SCXI chassis, th e host computer, and the SCXI device. Re: strain gage calibration using Signal Express vtttt. This number has 2 user reports. 1 NI-DAQmx 7. We're using a scxi-1000 chassis with the scxi-1520 module and scxi-1314 terminal block. com National Instruments Corporate Headquarters 11500 North Mopac Expressway Austin, Texas 78759-3504 USA Tel: 512 683 0100 Worldwide OfficesSCXI-1327 Installation Guide 2 ni. 0. All Manuals. The sampling rate was set at 1000 Hz, the cut-off frequency of the low-pass filter at 100 Hz, and the strains for a given applied load were. Detailed Name. The problem I'm having is that t. I am trying to connect a Celesco PT101-xxxx-xxx-1110 cable extension transducer or wirepot to a SCXI-1520 module using the SCXI-1314 terminal block. $259. The SCXI-1330 kit has 32 terminals (rows A and C, even-numbered pins only). SCXI-1520으로 트랜스듀서에 전원을 인가하고 응답을 모니터링하려고 합니다. 326 National Instruments ¥ Tel: (800) 433-3488 ¥ Fax: (512) 683-9300 ¥ info@ni. 2. Note: For most purposes, the SCXI 1001 needs either a 1520 or 1540 module on-board as a communicator. what do I need to do to get a reading on my thermistor?SCXI -1314 Installation Manual. Part Number: SCXI-1314: Manufacturer/Brand: Equipment: Description: National Instruments 197882A-01 High-Voltage Attenuator Terminal Block: Speak to a sales representative for pricing & lead time: Phone:SCXI- 1000 Chassis w/ 1346 adapter PCI 6281 DAQ card SCXI- 1520 Bridge Board w/ 1314 Terminal Block (x2) SCXI- 1180 Feedthrough Panel w/ 1302 Block Signal Express 2014. With this system, it is only possible to measure the deflection of. 120. SCXI-1520 - 4 nos. I even pulled the shunt wires from the terminals since I'm trying to condition based on a mV/V sensitivity and not a shunt. 압력 scxi daq 시스템에 권장되는 스타터 키트: scxi-1600 daq 모듈. It features a 10 V maximum voltage measurement range. This combination allows the user to easily link strain gauges via screw terminals. Close and lock the enclosure door. Stock # 94460-1 . Phone 2362371314 has a negative user rating. We are using a SCXI-1520 with a SCXI-1314 accessory with the intention of using it with some full bridge and half bridge strain gauges. I would also like to mention that the 2nd module had also the same problem with the 2nd similar chassis. There are 10 pins arranged in eight modular jacks. Rtds. Then, follow the steps below: 1. PCI-6052E DAQ board 2. The task uses a SCXI-1000 chassis with a SCXI-1520 module and a SCXI-1314 terminal block. $200. Hi, How to configure in MAX the SCXI 1314(PXI 1052 and 1520) to take load cell measurement? I tried to create a task usin analog input ->strain, but it does not work. Current Excitation. 326 National Instruments ¥ Tel: (800) 433-3488 ¥ Fax: (512) 683-9300 ¥ info@ni. Can anybody help?an SCXI-1314 terminal block, connect the DMM to the P0+ and P0– output terminals of the SCXI-1314. I'm guessing that channel 2 of your 1314 has a 120 Ohm resistor installed, and the other channels. com bold Bold text denotes items that you must select or click in the software, such as menu items and dialog box options. The terminals labeled VCC on the SCXI-1326 terminal block are not used with the SCXI-1162HV or the SCXI-1163R. SCXI-1308. The sequence File»Page Setup»Options directs you to pull down the File menu, select the Page Setup item, and select Options from the last dialog box. Do not loosen or re-orient the safety-ground lug hardware when connecting the safety ground wire; to do so reduces the safety isolation between the high voltage and safetyThe uniaxial gauge (gauge factor of 2) is in a quarter-bridge configuration (2. 3. National Instruments SCXI-1314 Terminal Block This National Instruments SCXI-1314 Terminal Block is used and in good condition. For a complete description of. SCXI-1321 Terminal Block. It also has a 1120 card w/SCXI 1303 terminal block with type K thermocouple installed. 5 N/m) is used with the piezoresistor scanning probe channels connected to a National Instrument SCXI Universal Strain Gauge Module (SCXI-1520 and SCXI-1314) using a shielded cable. Scxi 1314 Manual. National Instruments NI PXI-6259 M Series Multifunction DAQ Board. This document provides the steps to install and. SCXI-1321 Terminal Block. . If I wire the output end to S- (negative output) instead of S+, is my result just thecard (SCXI-1314, SCXI-1520, SCXI 1000, and PCI-M6221, respec-tively, NI) using Labview 7. Page 5 Reinstall the top cover and tighten the top cover screws. Member AuthorThe SCXI-1326 terminal block is a shielded board with supports to connect it to the module front connector. In this case the sampling rate was limited by the laser sensor and was set at 3 kHz. Order international: +1 609. I have a manufactured load cell that I'm plugging into an SCXI-1314 wired for full bridge. Wind tunnel velocity was determined three ways: a pitot-static tube and water manometer. Right click SCXI-1520 and select Properties from the menu that pops up. The connection string would be extensometer---> SCXI-1314 (Terminal)---> SCI 1520 (block 2). 113. Re: SCXI 1520. Should I do anything differently? images. Support Worldwide Technical Support and Product Information ni. 7 /5 based on 8 ratings. Otherwise, you'll probably want to reference this KB on DAQmx calibrations . Presented by Photography and Floor Plans by CMC Photo and Measure ServicesPhotography | Floor Plans | RMS Measurements | 3D Tours | Video | Drone |. 115. Set the following parameters: • SCXIchassisID—The value assigned by MAX • moduleSlot—1 • moduleChan—The channel number from step 3 • excitationType—2The SCXI-1314 has eight possible channels for strain gage connections. National Instruments SCXI-1313A- 8 input channels: Call: SCXI-1314: National Instruments SCXI-1314- for use with the SCXI-1520: Call: SCXI-1315: National Instruments SCXI. Click Reprogram. SCXI-1314 PLCs/Machine Control from NATIONAL INSTRUMENTS 2-Year Warranty, Radwell Repairs - DISCONTINUED BY MANUFACTURER, TERMINAL BLOCK, LOW VOLTAGE. The task uses a SCXI-1000 chassis with a SCXI-1520 module and a SCXI-1314 terminal block. {"payload":{"allShortcutsEnabled":false,"fileTree":{"":{"items":[{"name":"1. 121. I have problem with obtaining strain with SCXI 1520 (with terminal block 1314). BNC-2111 Installation Manual. . rev: 3. Signal Conditioning SC-2345/2350 Carrier User Manual SC-2345/2350 Carrier User Manual July 2007 371064F-01. It is understood that DAQ card channel zero is used to multiplex and measure. I have a test where I am measuring several channels of displacement measuring potentiometers, several quarter bridge strain gauges, a. This terminal block includes a factory installed and socketed 350 Ohm quarter-bridge completion resistor for each channel. An SCXI 1349 cable assembly connected the chassis, and delivered the data to the computer through a. Page 4 DAQ device and the SCXI-1520. SCXI-1520 to SCXI-1314 Half-Bridge Connection. system allowed sampling at 12 ms intervals of all force transducers in. Shunt. This strain data is used to calculate a slope, then scaled in software so it can be read as load cell which outputs Lbf. Part Numbers:187212B-01, 777687-14 SCXI-1127. Author's personal copy. 1 cm SCXI-1320 Installation Guide 4 ni. Free essays, homework help, flashcards, research papers, book reports, term papers, history, science, politicsIn the figure below, a connection diagram for wiring a strain gauge has been illustrated. TC-2095 Calibration Procedure. . We have New & Used SCXI-1314 Terminal Block by National Instruments In Stock & ready to ship! Request a fast quote or call 1-800-915-6216 now to get your price on all National Instruments models. I have a few questions about how signal express. I am developing an application to apply the SCXI-1314 shunt resistors to 250 strain gages for calibration. 5. 119. SCXI-1313 Parts Locator Diagram 4. 115. They are socketed,so you can replace them with your own resistors. I am trying to read a Sensotec load cell - model 41 (50,000 lb). I would like to use VI Logger to datalog pressure transducers (strain gage type) using SCXI-1520/SCXI-1314. . Cell. 10 pages. View Photo of missing side panel. Resistors shipped with the SCXI-1314 are 120 Ω and 350 Ω RN-55 style (standard 1/4 W size). The SCXI-1314 terminal block is used with the SCXI-1520 universal strain/bridge module enabling you to conveniently connect strain gauges through screw terminals. 2) For the SCXI channel to view, use the following convention OB0!sc (n)!md (m)!ch where the letter (n) corresponds to the chassis number in MAX (usually = 1), the letter (m) corresponds to the module number (slot) where the module is located in the chassis, and (ch) represents the. I'm stuck. The NI SCXI-1322 has an onboard sensor for cold junction compensation and can be utilized for many types of measurement applications. SCXI-1520으로 트랜스듀서에 전원을 인가하고 응답을 모니터링하려고 합니다. NI SCXI 1314 (Fig. 2Recommended for thermocouples; includes isothermal design and high-precision CJC sensor. Each group corresponds to one of the eight channels available. The SCXI-1314 (Part Number: 777687-14) is created for use with the SCXI-1520 universal strain/bridge module. Slow" SCXI Signal Conditioning PXI chassis "A" (sianal conditionina and 24-bit digitization) Fast" SCXI Signal Conditioning. 0 Kudos Message 7 of 9 (8,222 Views) Reply. National Instruments NI SCXI-1314 Terminal Block for SCXI-1520 Module. (Output 4 ~ 20mV, excitement: 12-30Vdc)Hi usuario, You're right when you say 'shunt resistor' in ' DAQmx Perform Shunt Calibration (Bridge)' VI stands for the value of shunt resistor in ohm. The 88 screw terminals on. The SCXI-1314 and SCXI-1520 was employed with the SCXI-1000 chassis for the torsional measurement of torque tube. NI Supported Device Terminal Block SCXI-1520 SCXI-1314 PXI-4220 N/A SCXI-1121 SCXI-1320 SCXI-1122 SCXI-1322 SCC-SG24 N/A Related Links: NI-DAQmx Example: Ready-to-Run Strain Measurement NI-DAQmx Example: Digital Filtering with the SCXI-1520 NI-DAQmx Example: Nulling all Channels in a Custom Voltage with Excitation Task. Figure 1 shows the SCXI-1325 terminal block parts locator diagram. SCXI TM SCXI-1520 User Manual SCXI-1520 User Manual May 2009 372583E-01. It depends on how you're looking to do the calibration- to do a full calibration, you would want to reference the 1520 link that Chris posted, which requires a Fluke 5700A along with a DMM. 5 or later, and the latest release of NI. 00. Half-bridge completion is provided in the SCXI-1520, and you can enable it through software. connect the SCXI-1001 containing the SCXI-1520 & SCXI-1314. 2. The DC coupled device has 8 analog input channels. I am using DAQmx Vis to program. scxi-1314 ターミナルブロックからカバーを取り外します。 2. 3. If you plan to use an SCXI-1104 or SCXI-1125 with a Remote SCXI configuration, you must update the firmware on your SCXI-2000 chassis or SCXI-2400 module. The system was built in. Analog Output Channel Signal Connections on the SCXI-1124. The value of strain do display in LABVIEW EXPRESS. The National Instruments SCXI-1102 and SCXI-1112 are designed for high-accuracy thermocouple measurements. $200. Now, I need to calibrate the extensometer (OFFSET REMOVAL and CALIBRATION of SHUNT). SCXI Terminal Blocks Overview National Instruments SCXI terminal blocks provide a convenient method for connecting and disconnecting signals to your system. external reference voltage for analog output. SCXI-1314는 AIGND를 위한 스크류 터미널을 가지고있지 않지만, 당김 방지(strain-relief) 막대의 한쪽 끝에 위치한 케이스 나사에서 샤시 그라운드에 연결할 수 있습니다. I can not use MAX because I use custom strain gage VIs that convert the input voltage i. Rtds. MAX is showing all hardware ( DAQ card + Chassis + SCXIs), set in Multiplexer mode. Mod5: SCXI-1520. 121. Industrial-Grade Solutions Smart Buildings Software Defined Labs Video Surveillance Network Monitoring Services. If you love a cozy, comedic mystery, you'll love this 'whodunit' adventure. . For larger systems, or future expansion, you can also daisy chain up to eight SCXI‑1000 chassis with a single multifunction I/O device or module for. I'm stuck. I'd like to know if it's possible to do a hardware synchronization between SCXI-1600 and a "PCMCIA CAN/2 series2"? I have the cable to connect the PCMCIA connector "sync" to the PFI7 and PFI0 of the SCXI-1600, but in Labview, when I select the Dev1/PFI7 as source of "DAQmx Timing. . The value of the strain appear in LABVIEW EXPRESS. The uniaxial gauge (gauge factor of 2) is in a quarter-bridge configuration (2. I am usin. . 9. Connector Accessory for E/M/S Series Devices. Analog Output Channel Signal Connections on the SCXI-1124. Popular SCXI Parts Include: SCXI-1100. 9514-16. SCXI Module Wiring A. If you are using a device in Traditional NI-DAQ (Legacy), refer to the Terminal Name Equivalents table for the Traditional NI-DAQ (Legacy) signal names. Hi, How to configure in MAX the SCXI 1314(PXI 1052 and 1520) to take load cell measurement? I tried to create a task usin analog input ->strain, but it does not work. Half Bridge Schematic for SCXI Strain Components In order for LabVIEW software to integrate with NI data acquisition hardware and read the data, SCXI hardware needs to be virtually installed in LabVIEW environment. I connected the lead wire to the S-, P+, and QTR pins of SCI 1314. Current Excitation. REPORT DOCUMENTATION PAGE Public reporting burden for this collection of information is estimated to average 1 hour per response, including iNational Instruments SCXI-1322 Temperature Sensor Terminal Block. com. Find the National Instruments SCXI-1317 at our website: Click HERE. Please see my Sig for current hardware specs. 2) For the SCXI channel to view, use the following convention OB0!sc (n)!md (m)!ch where the letter (n) corresponds to the chassis number in MAX (usually = 1), the letter (m) corresponds to the module number (slot) where the module is located in the chassis, and (ch) represents the channel. The SCXI-1304 AC/DC is a shielded terminal block with screw terminals that you can connect to the SCXI-1140, SCXI-1141/1142/1143, SCXI-1120/D, SCXI-1125, or SCXI-1126 input connector. 7. 1 SCXI-1000 SCXI-1520 SCXI-1314 PCI-6031E Windows 2000 Greetings- I'm trying to determine how the gain that is settable on a given channel of an SCXI-1520 module is combined with the gain that NI Max assigns to a Virtual Channel. When you configure your SCXI-1520 in Measurement & Automation Explorer (MAX) you can also assign an accessory such as the SCXI-1314T to the module. Check for open ports on the device 3. Page 1 SCXI -1314T TEDS Bridge Sensor ™ Terminal Block This guide describes how to install and use the SCXI-1314T terminal block with the SCXI-1520 module and hardware Transducer Electronic Data Sheet (TEDS)-enabled bridge sensors (IEEE-P1451. In addition, the SCXI-1520 system offers a half-bridge completion resistor network in the module and a socketed 350 W quarter-bridge completion resistor. With this system, it is possible to measure only theherein are trademarks or trade names of their respective companies. The SCXI‑1520 can measure strain gauge configurations including quarter‑, half‑, and full‑bridge configurations. Expand the NI-DAQmx SCXI Chassis section and choose your chassis model and click Finish. You can add insulation or padding if necessary. x를 어떻게 설정해야 하며, 이 트랜스듀서를 위한. My sensors are attached to a SCXI-1314 modle in a 1520 box in channel 0 (positioned as in the manual for half bridge) with the completion resistors in the appt places in ch7. Note When connecting your signals to the SCXI-1327, follow the labeling on the SCXI-1327 for the appropriate module, as indicated in Figure 2. 8. 68. . I have connected one strain gauge as quarter gauge-I configuration in one channel. Re: Calibration of scxi-1520 and scxi-1314. The policy on the equipment use outlines the recommended procedure for the sharing of CREPEC infrastructure recommended by the members of the CREPEC Executive. italic Italic text denotes variables, emphasis, a cross reference, or an introduction to a key concept. Ships in 5-10 Days. B-2 B. The task has been configured from a full bridge type-I strain gauge with internal excitation. Refer to the SCXI Quick Start Guide to power on the SCXI chassis and configure the system in software. 00. NI TB-2630 Installation Instructions Manual. Analog Circuitry in the SCXI-1122. shunt-calibration and quarter-bridge resistors of your SCXI-1314 terminal block. Figure 4-10. Page 8 Tighten the terminals to a torque of 5-7 in. 10. 6, NIDAQmx 8. EN English Deutsch Français Español Português Italiano Român Nederlands Latina Dansk Svenska Norsk Magyar Bahasa Indonesia Türkçe Suomi Latvian Lithuanian český. This document contains information and step-by-step instructions for verifying the value of the shunt-calibration resistors, the value of the quarter-bridge resistors, and the performance of the temperature sensor on the National Instruments SCXI-1314 terminal block. SCXI TM SCXI-1520 User Manual SCXI-1520 User Manual May 2009 372583E-01. Win7 Enterprise. 1520. the "Start Installation" window during the install. When I condition and calibrate the load cell as a Full-Bridge Strain channel (shunt cal) my signal output is POSITIVE in compression. AU $678. connecting RS technology torque convertor to the wiring board of a ni scxi 1314, whats the best way considering that this reads botht the inputLabVIEW 6. If you plan to use an SCXI-1104 or SCXI-1125 with a Remote SCXI configuration, you must update the firmware on your SCXI-2000 chassis or SCXI-2400 module. SCXI-1129. SCXI-1181K SCXI-1301 Ð Ð SCXI-1520 SCXI-1314 Ð Quarter-bridge completion/shunt resisterSCXI 1191; SCXI 1192; SCXI 1313; SCXI 1314; TBX 1316; Products Supported in Prior Versions of NI-DAQ Not Supported in This Version. Half-bridge completion is provided in the SCXI-1520, and you can enable it through software. The SCXI-1314 terminal block provides screw terminals for easy connections to your sensors. I have a manufactured load cell that I'm plugging into an SCXI-1314 wired for full bridge. Figure 2. 4. Show More Description. I am an undergrad research asst. Rush Available. The BNC-2111 is an adapter you can connect to data acquisition (DAQ) devices. LabVIEW software was used for data acquisition from K-type thermocouple and strain gauges. 4-12. The quarter-bridge completion resistor has a factory default value o f 350 Ω for use with a 350 Ω strain gauge. 0 Kudos Message 9 of 24 (7,773 Views) Reply. The National Instruments SCXI-1314 Terminal Block is a front-mounting terminal block for the SCXI-1520 universal strain gauge input module, for use with 350 Ohm quarter bridge strain gauges. If you have an SCXI-2000 chassis, right-click its folder and select Properties. com ¥ ni. This acquisition 14 C. Contents. The P15660 Team is using spare strain gauges to the current rotating frictionI am using PXI 1052 chassis with PXI-6221 DAQ card with SCXI 1520 and SCXI 1314 terminal block. Using the SCXI-1317 terminal block with the SCXI-1521/B module enables you to conveniently connect quarter-bridge strain gauges. Tighten the terminal screws to a torque of 0. Shunt. groups of 11. I have the serial cable from the load cell connected to a SCXI-1314, SCXI-1520 Module, SCXI-1000 Chassis, and to a Traditional DAQ Card in the PC. SCXI-1349 cable assembly 4. SCXI-1314 Shunt-Calibration Resistors and Quarter-Bridge Resistors R1 RPJ R2 R3 UJ SCB SCB SCB SCB SCA SCA SCA SCA QTR QTR. 117. . . The strain levels range from about zero to +/-1000ue (microstrain), and according to the NI 'Measuring Strain with Strain Gauges' tutorial this. ThanksNI SCXI-1304 NI SCXI-1306 NI SCXI-1314 NI SCXI-1315 NI SCXI-1326 NI SCXI-1600. 4. You also need either the SCXI‑1314 or SCXI‑1314T front mount terminal block to use the SCXI‑1520. 326 National Instruments ¥ Tel: (800) 433-3488 ¥ Fax: (512) 683-9300 ¥ info@ni. To evaluate injurious loads, while considering relevant energy input and body posture for a sideways fall, a subject-specific cadaveric impact experiment was. SCXI-1338 Installation Manual. These gauges are attached to two cylinders. Is there a particular reason you are choosing to use the lower resistance for your calibration?I have attached a picture of how the sensor should be connected to the SCXI-1314 terminal block. com ¥ ni. I'm going to address your last question first. Should we attach the ground wires to theThe Wheatstone-bridge used was a half-bridge type called quarter bridge II in the Measurement and Automation Explorer software of National Intrument (NI) strain-bridge ref. The SCXI-1314 is a National Instruments Terminal Block with a Compatible Module SCXI-1520 . scxi-1161 - - モジュール内にスクリューターミナル装備 scxi-1162/hv scxi-1326 - - scxi-1163/r - scxi-1180 scxi-1302 - 50ピン端子台 scxi-1181 scxi-1300 - scxi-1181k scxi-1301 - - scxi-1520 scxi-1314 - クォータブリッジ構成/シャント抵抗 scxi-1540 scxi-1315 - - scxi-1581 scxi-1300 - -SCXI-1338 Installation Guide 2 ni. The terminal block and strain input module were housed by an NI SCXI 1000 Chassis. Free shipping. For an upcoming test we plan to use an old SCXI-1001 chassis, an SCXI-1600 Daq, and 7 SCXI-1520's along with the SCXI-1314's to measure 50+ channels of strain gages. It was just difficult to see since I was almost standing on my head while trying to read that little number. 6. Leave jumper W1 on the SCXI-1100 in the factory-default (parking) position. Hello, The 1314 should have no problems with a 700 ohm full bridge load cell. . From quarter-bridge II configuration I try to measure initial voltage, then load the system, obtain resulting voltage and then use Convert Strain Gage Reading. 4. Data acquisition was accomplished utilizing a desktop computer and a National Instruments NI SCXI-1314 analog to digital conversion module. flathead screwdriver, Number 1 and 2 Philips-head screwdrivers, and the Installation Guide/User Manual. Terminal Block National Instruments SCXI -1314 Installation Manual. Figure 6. Win7 Enterprise waveform minmax. 市場投入までの期間がますます短くなりつつある中、多くのチームは製品の品質を管理することに苦労していますが、クラス最高のテスト組織がその道を切り開いています。The SCXI‑1520 can measure strain gauge configurations including quarter‑, half‑, and full‑bridge configurations. All reports are written by real visitors of this website. SCXI-1314 Printed Circuit Board Diagram The following illustration shows the locations of the SCA and SCB resistors, the quarter-bridge resistors, and channels 0 through 7 of the SCXI-1314 terminal block. I connected wires from strain gage to SCXI 1314 connector block which is then connected to SCXI 1520, placed in chassis. Find many great new & used options and get the best deals for NI National Instruments SCXI-1314 Terminal Block for SCXI-1520 Module at the best online prices at eBay! Free shipping for many products!I am using an SCXI 1001 chassis, SCXI-1600 USB DAQ, and an array of SCXI 1520 and 1314's for strain measurements. The terminals labeled GND are not used on the SCXI-1162. The DC coupled device has 8 analog input channels. Specifications All specifications are typical at 25 °C unless otherwise specified. jpg","contentType. I am measuring higher values of strain then I am expecting. Call SCXI_Set_Excitation to set the excitation voltage to the desired value. The informationThe NI SCXI-1324 (Part Number: 777687-24) is ideal for high-voltage general-purpose switching applications. Internet Access Control Manual, Tefal Aquaspeed 170 Manual, Insignia Home Theater Manual, Eos M280 Manual, Netopia R910 Manual, Canon Eos Xsi 450d Manual, Scxi 1314 Manual yunqian 4. Thanks In adva. ref: fkm7845The SCXI-1314 includes a factory installed and socketed 350 Ohm quarter-bridge completion resistor for each channel. 57 to 0. Per the SCXI-1314 Terminal Block Calibration Procedure, there are two 100K high precision resistors installed to be used for shunt calibration procedures. . Hi, Jake. ni 중고 NI 중고 계측기 중고 DAQ 중고 SCXI 중고 cRIO 중고 PXI 중고 ni중고 NI중고 계측기중고 DAQ중고 SCXI중고 cRI. made in hungary. Am Getting Inaccurate Readings When Some Channels of the SCXI-1520/SCXI-1314 Are Open Circuits My hardware is :- PCI MIO 16E-1 - 1 no. SCXI 1314 is the connector block where you wire the strain gauges in quarter/half/full bridge configuration. I also c. This document contains information and step-by-step instructions for verifying the value of the shunt-calibration resistors, the value of the quarter-bridge resistors, and the. Module: SCXI-1520; 8-chan. Do not connect anything else to the DAQ board. Hi Ron, You can send them to OR get these calibrated, or you may have a local company. I guess I'm going to have to reinstall. I'm using an SCXI-1520 (with SCXI-1314 terminal block) connected to an SCXI-1001 and communicating with my computer through a PCI-6221 DAQ card. 1553. Should I use 5 cables per channel and p. Providing accurate control systems in rehabilitation robotic has been a challenge for researchers. They are socketed, so you can replace them with your own resistors. In this case the sampling speed was limited by the laser sensor and was set as 3 kHz. (Refer to Figure 2 for a diagram of.